- Innovative Product Series
- In vitro diagnostic reagents and consumables
-
Sample pretreatment
- Column Plate For Nucleic Acid Extraction
- Solid Phase Extraction Spe
- Tip SPE
- Pre Treatment Columns For Ion Chromatography
- Blank Flash Columns
- Liquid Liquid Extraction Sle
- Affinity Chromatography Ac
- Medium Pressure Chromatography Columns High Pressure Chromatography Columns
- Dispersive Solid Phase Extraction Quechers
- Serum Pipette
- Cell Culture
- Filtering Apparatus
- Laboratory filters
- Automated intelligent devices
- Maintenance Of Technics
2 mL Purification Columns Small Nucleic Acid Is...
B&M® purification columns are packaged with fiberglass membranes, a technology based on the rapid extraction of nucleic acids by glass fiber extraction. The columns can be used to purify single- or double-stranded DNA or RNA in the presence of impurities such as salts, solvents, enzymes, or proteins. Nucleic acids are adsorbed on the glass fiber at a high concentration of salt, salt and impurities are removed at the washing stage; Pure DNA/RNA is washed off the membrane with water or TE buffer.
Nucleic Acid Isolation Columns 4.5 mL Centrifug...
B&M's® nucleic acid purification columns are based on the classic silica gel membrane technology. Under conditions of high salt content and low pH, nucleic acids are adsorbed on the silica gel membrane, while impurities such as polysaccharides and proteins are not adsorbed. Further rinsing removes the remnants of impurities. Finally, pure nucleic acids are produced by elution with a slightly saline solution or pure water.
Nucleic Acid Isolation Columns 25 mL Plasmid Is...
The B&M® Large Nucleic Acid Purification Columns are based on the classic silica gel membrane technology. Under conditions of high salt content and low pH, nucleic acids are adsorbed on the silica gel membrane, and impurities such as polysaccharides and proteins are not adsorbed. Further rinsing removes the remnants of impurities. Finally, pure nucleic acids are produced by elution with a slightly saline solution or pure water.
96-well removable microfiltration plate for nuc...
B&M's® 96-well removable microplates for nucleic acid isolation are based on the classic silica gel membrane technology. Under conditions of high salt content and low pH, nucleic acids are adsorbed on the silica gel membrane, and impurities such as polysaccharides and proteins are not adsorbed. Further rinsing removes the remnants of impurities. Finally, pure nucleic acids are produced by elution with a slightly saline solution or pure water.
24/96/384 well nucleic acid extraction plate is an auxiliary material for high-performance nucleic acid extraction and separation, which is mainly used for primer desalination, enrichment, extraction and nucleic acid separation. It can conveniently and quickly process 24, 96, 384 biological samples as 24/96/384 biological samples for the purpose of separation, extraction, beneficiation, desalination, purification, recovery, and so on.
HLB Column Plates for Solid Phase Extraction
B&M® HLB is a solid phase extraction column based on N-vinylpyrrolidone and divinylbenzene. The combination of hydrophilic and hydrophobic groups on the surface results in balanced adsorption of a wide range of polar and non-polar compounds, and the adsorbent retains a high adsorption capacity even after equalization and draining. This means that very high sensitivity can be achieved with a simple method. The matrix is pure, stable in the pH range of 0-14, stable in a wide range of organic solvents, and has a high adsorption capacity (3-10 times higher than that of C18). It is mainly used for the extraction of complex biological samples (e.g., blood, plasma, acidic, neutral, or basic drugs in body fluids).
Equivalent to Waters Oasis HLB.
C18 Tip SPE Pipette TipsExtraction Tips
B&M® Tip C18 pipette tips contain a silica monolith bonded to C18 (octadecyl). Silica monolith has a continuous structure with through holes. By combining with C18, the B&M®Tip C18 allows proteins and peptides to be desalted and concentrated in reversed-phase mode by easy pipetting.
Sample Pretreatment Columns for C18 Ion Chromat...
During ion chromatographic analysis, impurities are often present in the sample.
For example, organic substances contaminate the packaging of an ion-chromatographic column, reduce the separation ability of the column
and column life, and impurity ions will interfere with the separation of target ions.
BM Life Sciences' B&M® IC Series ion chromatography sample pretreatment columns are designed based on the solid state principle.
Flash Blank Columns Fast Liquid Chromatography ...
B&M® Flash Column Series: Flash is a fast separation mode for preparative chromatography, using optimized medium and low pressure prepackaged columns for chromatographic separation; used to purify organic compounds, it is a fast and inexpensive method compared to traditional column chromatography; Widely used in drug discovery and development, sample and natural product purification, and other applications.
Our company independently developed 4G-1600G a complete set of shape specifications, including tube columns, cap, standard top and bottom cover luer connector and 2 pieces of sieve plate, the tube column material is medical grade polypropylene injection molding; independent development, cost-effective, stable supply, quality assurance; Welcome customers to consult and discuss cooperation!
Affine chromatography column (gravity column)
BM Affinity Chromatography Columns (Gravity Columns) Series: 1ml-550ml with hydrophobic/hydrophilic sieve plate (sieve plate aperture can be selected from 5-100um); The column body is made of medical-grade polypropylene by single injection molding, which has very low adsorption on various biomolecules; The sieve plate is made of high-purity ultra-high molecular weight polyethylene (UHWMPE) with special technology; It can be used for Nickel Loading Column (Ni-NTA), Agarose with Protein A, Agarose with Protein G, Agarose with Protein A+G and other common media for affinity chromatography; Suitable for the separation and purification of proteins, antibodies, proteins labeled with biotin or digoxigenin, or nucleic acids containing various labels such as His-tag, and other substances suitable for affinity chromatography. Separation and cleaning.
Chromatography Columns Protein Purification Col...
Medium Pressure Chromatography (MPCC) columns are designed for the purification of antigens, antibodies, recombinant proteins, and protein desalination. They are a powerful purification tool for antibodies, proteins, and other molecules and can be filled with chromatographic media for immunoaffinity, ion exchange, gel filtration, and reversed-phase separation mechanisms, as required. Medium-pressure chromatographic columns are suitable for liquid-phase cleaning systems (e.g. ÄKTA cleaners) and can also be connected to syringes or peristaltic pumps.
Needle Filter (CELL Membrane)
Needle filters are disposable membrane-type devices used to remove solid impurities from liquid and gaseous samples prior to analysis by methods such as HPLC, ion chromatography, gas chromatography, ICP, and dissolution tests. Proper sample filtration improves the quality and consistency of analysis results and reduces instrument downtime. For fast and effective filtration, disposable needle filters are usually used. The choice depends on the specific application. Sterile needle filters can be used to sterilize or clarify sterile solutions, while non-sterile needle filters are used for general filtration and sample cleaning.
Needle filters are classified according to two main characteristics: membrane and housing. Both characteristics must be adapted to the application conditions and the filtrate. Needle filter membranes are selected according to the material, filter diameter and pore size, while needle filter housings are selected according to the final application in terms of material and style.
Specification Diameter: 13mm 25mm 33mm
Membrane pore size: 0.10μm 0.22μm 0.45μm 0.80μm
Membrane Type: MCE NYLON PVDF PES PTFE CA SFCA PES etc
Zymography Plate
B&M® Enzyme Labelling Plates are made of a special material, polystyrene, which is a safe, reliable and effective carrier for ELISA and plays an important role in the adsorption of antigens, antibodies or antigen-antibody complexes.
B&M® Enzyme Label Plates have a unique surface treatment for perfect results and are widely used in ELISA tests such as immunization, identification of genetically modified foods and clinical diagnostics.